Nominal AC Voltage (50/60Hz) | 60 V | 120 V | 230 V | 230 V | 230 V | 400 V | ||
Maximum Continuous Operating Voltage (AC) (LN) | Uc | 75 V | 150 V | 275V | 320 V | 385 V | 440 V | |
(N-PE) | Uc | 255V | ||||||
Nominal Discharge Current (8/20 μs) (LN) / (N-PE) | In | 10kV / 10kA | ||||||
Maximum Discharge Current (8/20 μs) (LN) / (N-PE) | Imax | 20 kA / 20 kA | ||||||
Antas ng Proteksyon ng Boltahe (LN) / (N-PE) | Up | 0.2kV/1.5kV | 0.6kV/1.5kV | 1.3kV/1.5kV | 1.5kV/1.5kV | 1.5kV/1.5kV | 1.8kV/1.5kV | |
Sundin ang Kasalukuyang Interrupt Rating (N-PE) | Ifi | 100 ARMS | ||||||
Oras ng pagtugon | (LN) / (N-PE) | tA | < 25 ns / < 100 ns | |||||
Back-Up Fuse (max) | 125 A gL / gG | |||||||
Short-Circuit Current Rating (AC) (LN) | lSCCR | 10 kA | ||||||
TOV Makatiis ng 5s | (LN) | UT | 90V | 180V | 335V | 335V | 335V | 580V |
TOV 120min | (LN) | UT | 115V | 230V | 440V | 440V | 440V | 765V |
mode | Makatiis | Makatiis | Ligtas na Nabigo | Ligtas na Nabigo | Ligtas na Nabigo | Ligtas na Nabigo | ||
TOV Makatiis ng 200ms | (N-PE) | UT | 1200V | |||||
Mekanikal at Pangkapaligiran | ||||||||
Saklaw ng Operating Temperatura | Ta | -40ºF hanggang +158ºF [-40ºC hanggang +70ºC] | ||||||
Pinahihintulutang Operating Humidity | RH | 5%...95% | ||||||
Presyon at altitude ng atmospera | 80k Pa ... 106k Pa / -500 m.....2000 m | |||||||
Terminal Screw Torque | Mmax | 39.9 Ibf ·sa [4.5 Nm] | ||||||
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) | |||||||
35 mm2 (Solid, Stranded) / 25 mm2(Flexible) | ||||||||
Pag-mount | 35 mm DIN Rail, EN 60715 | |||||||
Degree ng Proteksyon | IP 20 (built-in) | |||||||
Materyal na Pabahay | ||||||||
Thermoplastic: Extinguishing Degree UL 94 V-0 |
Tumutok sa pagbibigay ng mga solusyon sa mong pu sa loob ng 5 taon.